SLR50 Nominal Voltage | 20AH Capacity | RC (min)
| Energy (kWH)
| Terminal Posts | Dimensions | Weight
| Charging Current*
| Charging Voltage
| Float Voltage
|
12V | 50AH
| 115
| 0.70 | 8mm (included)
| 7.8"w x 6.6"d x 6.7"h | 32lb
| 3A-15A
| 14.4-14.9V
| 13.5V-13.8V
|
Recommended Charging Options:
- AC
Chargers: Any Quality Brand AGM-
Smart & Microprocessor controlled- charger with the recommended specs above
can be used. Battery Charger Guide.
- Alternator: 14V-15V.
- RV Converter: 14V-15V.
- Solar Panel: 60W-225W (40W may be used if Depth of Discharge would not exceed 50%).
- Wind Turbine: 60W-225W.
- Charge Controller: 10A-20A.
* Warning:
Do not use a charger with smaller amperage than the recommended Charging
Current shown above.
Maintainers should ONLY be used to maintain a fully charged battery but NEVER
as a charger.
Operating Temperature Range:
- Discharge: -4~140F
- Charge: 14~140F
- Storage: -4~140F
Temperature Compensation:
- Cycle
use: -30mV/C
- Standby
use: -20mV/C
UPC: 760921777824
BCI Group Codes*:
Matching Termination: 21R (- on L.H.S. & +
on R.H.S)
* Matching is based on closest
dimensional specifications. Differences in hold downs and termination may
require some accommodations and/or the extension of one or both vehicle's
battery cables.